Podla mna budeš mat problém v rele žhavenia,ktoré odpalilo tu poistku...
PROFOR 110kw má už iný modul žhavanie a ten je napriamo a poistka je v nom v nutri, kus hlinikového pliešku ktorý občas prepali a potom prestane fungovať žhavenie!!!!
Ty si pozri to rélé žhavenia...treba ho vymenit,teda pokial si menil žhaviče za nové a nejde to.....
DDE 4.0
Preheating System DDE 4.0
The voltage for the preheater plugs is supplied via the preheater relay. The relay is switched by the DDE control unit.
The heater plugs are designed as sheathed-element glow plugs.
Preheater time control
The preheating duration is dependent on the engine coolant temperature and battery voltage and is indicated by the preheating/DDE indicator.
Preheating
At temperatures below 5 °C, preheating takes place for at least 4 seconds. The preheating time increases as the temperature decreases.
After-heating
After-heating takes place after engine start at temperatures below 20 °C in order to improve idle and exhaust characteristics.
Start preheating
Start preheating takes place for approx. 10 seconds if after the preheating time has elapsed the engine is not started and the ignition remain on.
Troubleshooting
The DDE control unit itself detects a short/break in relay activation (type of fault "activation short-circuit ..." or "activation break ..."). The DDE control unit receives a fault signal from the preheater relay in the form of the S_GRS signal if there is a fault in the preheater plugs, preheater relay or in the voltage supply of the relay (type of fault "preheater system fault"). Fault code 3505 "Preheating system" is stored in both cases.
DDE 5.0
Combustion preheating system DDE 5.0/5.1
The glowplug system consists of the following components:
DDE control unit
electronic glowplug control unit
quick-start glowplugs
Bit serial data interface (BSD) and electrical leads
A heater plug relay as in the case of DDE 4.0 is not fitted.
The quick-start glowplugs are designed for a voltage of between 5.3 and 7.8 Volts. In the initial heating stage, system voltage may also be applied for a short time.
The essential differences from the glowplug systems on previous models are as follows:
control of the glowplugs is by pulse width modulation
the glowplug relay has been dispensed with and its function taken over by electronic output stages on the glowplug control unit
an emergency glowplug function has been introduced
quick-start glowplugs have been introduced
each of the four glowplug circuits can be diagnosed individually
To check the glow system, there are two adapter leads:
1-pin, order number 13 6 470
12-pin, order number 13 6 460
in conjunction with 26-pin measurement box, order number 61 1 459
Function
The glowplug control unit communicates with the DDE control unit via the bit serial data interface.
The required heating output is determined by the DDE control unit on the basis of the following operational parameters:
Coolant temperature
Vehicle voltage
Two other operational parameters determine the point at which glowplug function is activated and deactivated:
Engine speed
Injection volume
The DDE control unit transmits the heating request to the glowplug control unit via the bit serial data interface. The glowplug control unit puts the request into effect by activating the glowplugs by means of a pulse-width modulated signal. In addition, the glowplug control unit sends diagnostic and status information back to the DDE control unit.
Preheating
At coolant temperatures below 25°C, there is a preheating period of 0.5 seconds. The preheating period increases as the temperature falls, reaching a maximum of 2.7 seconds at a coolant temperature of less than -25°C.
Activation of the glowplug system on the instrument cluster only occurs at coolant temperatures below 0°C.
After-heating
At coolant temperatures below 30°C, there is a temperature-dependent after-heating period to improve idling and exhaust emission characteristics.
Start preheating
Start preheating takes place for approx. 10 seconds if after the preheating time has elapsed the engine is not started and the ignition remain on.
Troubleshooting
The DDE control unit monitors communication with the glowplug control unit. In the event of a fault on the bit serial data interface, the DDE control unit stores the following fault code:
4203, Glowplug control unit, no communication via bit serial data interface
The glowplug control unit monitors activation of the individual glowplugs and is able to detect the following faults and store them for each glowplug:
Short circuit to earth
Break
Excess temperature output stage
If the glowplug control unit detects a fault, it reports it to the DDE control unit which stores the fault in its fault memory.
-